Examples of Engineering Service

Case for Technical Service (Noise)

Evaluation on Effects of Noise at Factory in ○○

Overview and Purpose
Design of measures for reduction of factory facilities generating noise according to occurrence of public complaints A site survey on generation of noises by the factory under the condition of normal operation / A optimal design of measures for reduction of noises from the factory
Criteria of Noise
Less than 45dB(A) at night in the region of public complaints
Scope of Performance of Project
Measuring and evaluating the noise level of the sources of noises and sound receiving points Noise analysis (simulation of sound field analysis) / Submission of a report on measures for reduction for facilities generating factory noises

Measures for Soundproof

Front View of Dust Collector
image
Fig 1. Sound Absorber on Exhaust Side of Dust Collector / Absorber
image
Result of Noise Analysis and Evaluation
Places expecting public complaints 60.3dB(A) before measures / 44.2dB(A) after measures which satisfy the criteria of 45dB(A)

- Fig 2. Measuring Noise

image
image

- Fig 3. 3D Modeling of Areas Expecting Public Complaints

image
image

- Fig 4. Before Measure for Combined Noise Level

Before Measure for Combined Noise Level
image
After Measure for Combined Noise Level
image
Evaluation on Effects of Noise of Railroad at Redevelopment Site in ○○
Overview and Purpose
Evaluation on effects of noises for apartment houses located nearby the railroad and subways Establishing a proper soundproof measure since inconvenience of residents of apartment houses since they move in.
Front View of Dust Collector
image
Criteria of Noise
Outdoor noise less than 65dB(A) / indoor noise less than 45dB(A)
Scope of Performance of Project
Measuring on-site noises during day and night / Analysis and evaluation on measured data Noise analysis before and after measure (Simulation) / Presenting a measure plan

Proposal of Soundproof Measure (Soundproof Wall)

Soundproof Wall
image
Result of Noise Analysis and Evaluation
Outdoor 63dB(A) / indoor 43.0dB(A) after measures for representative sound receiving point of the apartment house which satisfy the criteria
Fig 1. Analysis of Noise at Project Section
image
Fig 2. Measuring Maximum Noise by Lines
image
Fig 3. Measuring Indoor Noise During Daytime
image
Fig 4. Measuring Indoor Noise During Nighttime
image
Fig 5. The Whole View of Site
image
Fig 6. Analysis on Traffic Volume of Day Trains
image
Evaluation on Effects of Noise from Cogeneration Plant
Overview and Purpose
Selecting an evaluation region and determining an allowable noise criteria through identifying the peripheral status within the project section
Evaluating effects of noises at the site boundary of the power plant and the inside of the building due to noises generated by facilities in the power plant
Criteria of Noise
Less than 60dB(A) at the height of 1.5m of the site boundary [Allowable Discharge Criteria]
Evaluation on effects of noises at the boundary of a site of the power plant
Evaluating effects of noises at the boundary of a site of the power plant due to noises generated from main sources of noises
Performing an analysis by using a commonly used software that is proper for a 3D outdoor acoustic analysis
Result of Review
As for Air Inlet Filter and Transformer, they make a great contribution to noises of low frequency.

Measures for Soundproof

Fig 1. Transformer, Sound-Absorbing Type Soundproof Wall : H 9m
image
Fig 2. Air Inlet Filter, ALC Panel : H 14m
image
Result of Noise Analysis and Comprehensive Evaluation
1. Expected Noise Level Before Soundproof Measure 68dB(A)
2. Expected Noise Level Before Soundproof Measure 55dB(A)
3. Result of Noise Analysis Satisfying ‘less than 60dB(A)’ Which is the criteria of noise at the boundary of a site of the power plant
Result of Noise Analysis and Comprehensive Evaluation
image
Fig 3. Perspective of Site
image
Fig 4. Simulation Model (3D)
image
Evaluation on Effects of Noises at Generator Room of ○○ Research Institute
Overview and Purpose
Selecting an evaluation region and determining an allowable noise criteria through identifying the current state within the site
Evaluating on effects of noises at the site boundary of civil petitioners due to noise generated by a generator installed at a generator room
Criteria of Noise
Less than 60dB(A) in the morning and evening [Criteria of Noise for Living Environment]
Specification of Sources of Noises and Level of Generated Noise
Generator Model: C2000 D6, Cummins Power Generation
Max, Cooling Air Flow Static Restriction of Radiator: 0.127kPa (약 13mmAq)
- Exhaust Air Volume 1,888㎥/min
- Air Supply Volume 2,066㎥/min
Evaluation on Effects of Noises
Evaluating effects of noises at the region of civil complaints due to noises generated from a generator
Performing an analysis by using a commonly used software that is proper for a 3D outdoor acoustic analysis

Result of Noise Analysis

Fig 1. Schematic Diagram of Site
image
Fig 2. Noise Map of Noise Effect Evaluation
image
Comprehensive Evaluation
A sound absorber and a elbow-typed sound absorber, a noise elbow are installed at an inlet and outlet part of a generator room.
A soundproof wall is additionally installed at the exhaust part of the civil petitioner’s side
At all floors of the region of public complaints, it is the maximum 59dB(A) which satisfies the noise criteria of ‘60dB(A)’.

Noise Analysis Results and Comprehensive Evaluation

Fig 3. Generator
image
Measures of Soundproof for Factory of ○○
Overview and Purpose
Analysis level of contribution of sources of noises and establishing measures by steps through identifying the current state within the site
Evaluating effects of noises at the site boundary of the nearby residential area due to noise generated by facilities installed in the factory
Criteria of Noise
‘Less than 50dB(A)’ at the height of 1.5m of the site boundary [Allowable Discharge Criteria]
General of Site
Since the sources of noises are diverse, establishing measures for soundproof by steps is required.

Establishing Measures for Soundproof

Fig 1. Enclosure of Back Filter on Roof
image
Fig 2. Heat Conserving Casing of Bucket Line
image
Fig 3. Soundproof Louver at the Outlet of Cyclone
image
Fig 4. Sound absorbing works for a cyclone room
image
Fig 5. Heat Conserving Casing of Reducer
image
Fig 6. Installing a soundproof door at a boiler room
image
Fig 7. Installing a round sound absorber at the outlet
image
Fig 8. Enclosure of Main Material Back filter
image
Fig 9. Installing a soundproof louver at a compressor room
image
Comprehensive Evaluation
The targeted noise is about 49.0dB(A) at the site boundary of the nearby residential area after completing the measure of soundproof by steps, which satisfies the noise criteria of ‘Less than 50dB(A)’.
Fig 10. The Whole View of Site
image
Evaluation on Effects of Noise at Construction of Company Building of ○○ E&C
Overview and Purpose
Selecting an evaluation region and determining an allowable noise criteria through identifying the current state within the site
Evaluating effects of noises at external walls of a building due to noise generated by a cooling tower installed at the outside
Criteria of Noise
Less than 60dB(A) in the morning and evening [Criteria of Noise for Living Environment]

Status of Sources of Noises and Data of Penetration Loss by Types of Glass Windows (Unit : dB(A))

NO Quantity Type Capacity Location Noise Data (10m Separated)
Before Installing Sound Absorber After Installing Sound Absorber
CT-1 3cell / 2set Positive Blowing Typed Open Typed 3,315,000 4th Floor Roof Floor 78 53
CT-2 2,730,000 76 51
CT-3 1,755,000 72 49
CT-4 2,730,000 76 51
CT-5 1,755,000 72 49

Thickness of Glass(mm) Octave Band Center Frequency (Hz)
125 250 1K 2K 4K
5 + 12A + 5 21.1 13.9 28.9 30.5 29.0
6 + 12A + 6 25.3 19.8 31.2 27.4 33.5
8 + 12A + 8 24.8 20.6 26.0 30.7 41.0
10 + 12A + 10 25.3 23.4 32.8 25.9 45.4
Evaluation of Effects of Noise
Performing an analysis using a commonly used software that is proper for the outdoor 3D acoustic analysis
Evaluating effects of indoor noises after applying loss of penetration of walls and windows
Comprehensive Evaluation
After evaluating effects of noises for a cooling tower installed on the roof of the 4th floor and installing a noise reduction device (a sound absorber and a noise louver etc.) at the inlet/outlet of a low-noise typed cooling tower, it satisfied ‘less than 60dB(A)’ which is the criteria of noise at the site boundary or ‘less than 40dB(A)’ which is the criteria of noises at the inside of general offices as well.

- Fig 1. Result of Sound Field Analysis

image
image
Evaluation on Effects of Noises at Factory in ○○
Overview and Purpose
Selecting an evaluation region and determining an allowable noise criteria through identifying the peripheral status within the project section
Evaluating effects f noises at the site boundary and the nearby civil houses due to noise generated by facilities in the factory
Criteria of Noise
Less than 50dB(A) at the height of 1.5m of the site boundary
Overview of Project Section
A civil petition from a one-stored house at the point which is around 70cm away from the external wall of UT room.
Fig 1. Perspective of Site
image
Fig 2. Result of Plan Analysis (1.5m from the Ground)
image
Fig 3. Level of Noise at Main Sound Receiving Points(Installing a Soundproof Wall)
image
Comprehensive Evaluation
It is a reliable level since the error between the actually measured on-site data and the analysis result prior to the measure of soundproof is ±1dB(A).
After establishing measures for soundproof, it was found that it satisfied ‘60dB(A)’ which is the criteria of noise at the representative civil petition point.

Measuring/Analyzing Level of Noises by Frequencies of Main Sources of Noise

- Fig 4. P1: 73.5dB(A)

image
image

- Fig 5. P2: 61.9dB(A)

image
image

- Fig 6. P3: 51.3dB(A)

image
image
Evaluation on Effects of Noises of Data Center at ○○ Site and Design of Measures
Overview and Purpose
Evaluating effects of noises generated by facilities on the region of civil petition through identifying the peripheral status within the project section
Criterial of Noise
Less than 45dB(A) during nighttime of the region of civil petition
Overview of Project Section
Selecting and measuring a representative sound receiving point by considering the operation time of an exhaust fan
The level of noise measured at the yard of the newly constructed building which is an expected representative civil petition point was 62.1dB(A).
Fig 1. Noise Map(Plan) of Noise Effect Evaluation
image
Fig 2. Noise Map(Elevation) of Noise Effect Evaluation
image
Comprehensive Evaluation
Constructed a soundproof panel and a noise louver on the 3rd floor, a noise louver at the outlet of a fire extinguishing gas room and the outlet of an electricity room on 1~2nd floor
After establishing measures for soundproof, it was found that it satisfied ‘45dB(A)’ which is the criteria of noise at the representative civil petition points.
Fig 3. The Whole View of Site and Selecting Representative Sound Receiving Points
image
Fig 4. Measuring On-Site Noise
image
Case for Technical Service (Noise)

Breaker 70 ton (Rock Breaker Laboratory) Noise 120dB Control

Fig 1. Result of Indoor Noise Sound Field Analysis (Before Measure)
image
Fig 2. Result of Indoor Noise Sound Field Analysis (After Measure)
image
Fig 3. Result of Outdoor Noise Sound Field Analysis (Before Measure)
image
Fig 4. Result of Outdoor Noise Sound Field Analysis (After Measure)
image
Fig 5. Measuring Noise
image
Fig 6. Breaker
image
Fig 7. Exhaust Fan
image

F16K Aircraft Noise Control Laboratory (Soundproof) / Ministry of National Defense (Level of Noise 130~120dBA)

Fig 1. The Whole View of Site
image
Fig 2. Result of Indoor Noise Sound Field Analysis
image

Evaluation on Effects of Noise and Vibration of Main Block of ○○ Special Steel

Fig 1. The Whole View of Site
image
Fig 2. Result of Indoor Noise Sound Field Analysis
image
Case for Technical Service (Noise)

Standby & Emergency Generator Room Simulation

Fig 1. NOSE-MAP (ODEON)
image
Fig 2. NOISE-MAP (ENPro)
image

Evaluation of Effects of Outdoor Noise of Outdoor Units at ○○ Site

Fig 1. Location of Sources of Noise (Outdoor Unit Room)
image
Fig 2. Evaluation on Effects of Outdoor Noise
image

Applying Soundproof Measures through Review on Noise Analysis

Fig 3. Installation On-Site Sound Louver and Sound Absorber
image
Case for Technical Service (Noise)

Cases of Services and Construction of Soundproof Facilities for Generators at Multiple Sites other than Iraq

image
image

[Design/Delivery/Installation of Enclosure at OO Site in Iraq]
(ENCLOSURE FOR MDU IRAQ MOE DIESEL POWER PLANT)

Fig 1. Construction and Review of Enclosure BIM
image

Fig 2. Enclosure Manufacture Item Packing and Site Construction

image
image
image
image
image
image