Technology Institute

It was established with the goal of developing a "customer-inspiring solution"

Research Field

Evaluation on Performance of Spring Jack-up System
  • Evaluation Item Function of Frequency Response, Natural Frequency, Spring Constant etc.
  • Analysis Method Measuring vibration response at a vertical direction by impact excitation
- “Natural frequency less than 3.75Hz, The ratio of damping 1.67%”
Note Upon applying added mass, the natural frequency becomes lower.
Fig 1. Vibpilot M+P
image
Fig 2. Hammer: Dytran, Model 5803A
image
Fig 3. Manufacturing Mass for Experiment
image
Fig 4. Evaluation on Performance
image